A transformer is always considered a separately derived system. Nov 26, 2012 uses a power ground serves to provide a return path for fault currents and therefore allow the fuse or breaker to disconnect the circuit. Where an industrial power system includes powergenerating equipment, the. These systems are common in pv installations where there are two grounds such as an existing one for the ac system and a new grounding electrode that has been installed for the dc system. Shields is a comprehensive study guide for the design of industrial and commercial electrical power systems as dictated by neutral grounding and ground fault protection practices. Improper grounding or earthing of distributed control systems dcs or power electronic systems pes can result in either maloperation of the system controller or failure of electronic control cards or sometimes even the. Principle of switchmode power supply operation 225 4. So this tool was designed for free download documents from the internet.
The range of diameter for the earth rods vary from mm to 25mm mm, 16mm, 20mm, 25mm 3. Shields is a comprehensive study guide for the design of industrial and commercial electrical power systems as dictated by neutralgrounding and groundfault protection practices. To ground handbook and the international association of. This system avoids the risk of developing the first fault and eliminates subsequent risk of short circuiting due to second fault in the circuit. This guide is primarily concerned with safe grounding practices for power frequencies in the range of 50 60 hz. The basic principles of grounding of electrical systems the function of power system grounding and the various options available role of protective grounding in ensuring safety. He has published a number of research papers in this area in reputed national and international journals. The determination of short circuit currents in power distribution sys tems is just as basic and important as the determination of load currents for the purpose of applying circuit breakers, fuses, and motor starters. Characteristics of different power systems neutral grounding. The substation grounding grid is a system of horizontal, interconnected bare ground conductors, spaced a few meters apart, buried in the earth at a depth varying from 0. The main purpose of this work is the development of an optimization model for the design of the grounding grid in electrical substations. Sakis meliopoulos slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising. First, a simple equivalent circuit is developed for a generic power system, and then each of the options for neutral grounding is tested in that equivalent circuit to identify and understand the characteristics of the grounding method.
What would make a generator a separately derived system is if a transfer switch also switched the grounded conductor neutral. This is the second edition of the handbook of electrical design details hedd. Ieee recommended practice for grounding of industrial and. Pdf grounding system design in electrical substation. Electrically conductive materials that are likely to become energized shall be bonded to the supply system grounded conductor or, in the case of an ungrounded electrical system, to the electrical system grounded equipment, in a manner that establishes an effective path for fault current. Overview of grounding for industrial and commercial power. This book is a revision of ieee std 1421991, the ieee green book. With the development of economy and society, there are more and more modern industrial workshop, electricity is the main energy of a modern industrial workshop. Scope this guide addresses the high level aspects of policy associated with power system earthing. Role of switchmode power supplies in grounding system design 224 4. This paper is concerned with earthing practices and design for outdoor ac substation for power frequency in the range of 50 hz. Neutral grounded system the solution to above issue of ungrounded system is provided by a neutral grounded system.
Ieee guide for measuring earth resistivity, ground impedance, and earth potentials of a ground system. Associate professor, electrical and computer engineering, university of missourirolla. This recommended practice has served electrical engineers seeking electrical system grounding information since the first edition in 1956. A good grounding system should have the actual mesh and step voltages well below tolerable touch and step voltages respectively. If you want to safeguard all of your important assets, whether at home or at the office, as well as look out for the health and safety of everyone. Calculating procedures have been so greatly simplified compared. Many different methods can be used to implement a ground system, but. Earthing grounding of power electronic and distributed. Author probably the most comprehensive text that has been written for power systems grounding to date.
Duncan glover, et al, power system analysis and design, 5th edition, cengage learning, 2011. The terms connect and bond are used interchangeably in this section and have the same meaning. A grounded conductor is the conductor of an electrical system that is intentionally connected to earth via a grounding electrode conductor and a grounding electrode at the service of premises, at a transformer secondary, or at a generator or other source of electric power. Ieee guide for measuring earth resistivity, ground impedance, and earth potentials of a. Ac system grounding practices installing an effective ground system to achieve a good earthtogroundingelectrode interface is only half the battle for a facility designer. Pierre electric power consultants, 2007 electrical engineering 592 pages. Industrial automation wiring and grounding guidelines 5 publication 17704. The objective of designing safe grounding system is to provide easy and shortest path to the flow of. These installation details include power system and equipment grounding, static grounding protection for equipment in classified locations, grounding electrode connections, and step and touch potential grounding. Grounding your electrical system is a smart and easy way to make it a whole lot safer, as well as to protect against the very real possibility of having to deal with fluctuations in power supply. The first book to cover grounding from the circuit to system and across the entire spectrum of applications. You may purchase this handbook by either printing and completing the pdf order form and mailing in the form along with your check or money order. The book fully addresses the abovegrade grounding and belowgrade earthing issues related to article 250 of the 2014 nec and features indepth.
Grounding system design calculations 1 course description. Substations with critical consideration of the mesh, touch and step potentials article pdf available november 2017 with 3,100 reads how we measure reads. Ensure the safety of the power of the industrial building is a key consideration in the design of industrial distribution, and an important content of the healthy development of the. It provides a framework for managing earthing related risk associated with electrical power systems to meet societally acceptable levels. Industrial power systems handbook d o n a l d beeman, editor manager. In this type of grounding, one of the poles of the source is connected to the ground mass. Uses a power ground serves to provide a return path for fault currents and therefore allow the fuse or breaker to disconnect the circuit. The magnitude of the shoncircuit current is often easier to determine than the magnitude of the load current.
How to order industrial power system grounding design handbook. Filters also connect to the power ground, but this is mainly to stop the power ground carrying noise into the systems which the filters protect, rather than as a direct use of the power ground. Aug 23, 2016 power system grounding and transients. Earth rod dimensions depending on the design specification of the earthing system and the corresponding earthing wells, various earth rods of different dimensions would be incorporated. Finally a selection of case studies are presented to support the recommended practices presented throughout the.
Calculationofimportantdesignparametersforgroundingsystemsinsu. Finally a selection of case studies are presented to support the recommended practices presented throughout the book. Information on telecommunications system power protection as well as grounding, industrial system grounding, and noise control is included. Principles of electrical grounding john pfeiffer, p. In most other cases, larger systems are located within a defined plant environment 1. The problems peculiar to dc substations and the effects of lightning surges are beyond the scope of this guide.
This authoritative work presents detailed coverage of modern modeling and analysis techniques used in the design of electric power transmission systems emphasizing grounding and transients. Ieee std 1422007 revision of ieee std 1421991 ieee. Overview of grounding for industrial and commercial power systems. However, the design of a synchronous motor is so much like that of a. If you continue browsing the site, you agree to the use of cookies on this website. The problem is formulated as a mixedinteger linear. He has made significant contribution in the writing of the. Home about the book page facsimiles sketches who will read it about the authors how to order contact us. Earthing system thus design must be easily maintained and future expansion must be taken into account while designing the dimensions of earth mat.
Sep 10, 2015 ac system grounding practices installing an effective ground system to achieve a good earthtogroundingelectrode interface is only half the battle for a facility designer. It reflects the experience and sound judgment of a working group made up of engineers active in the design and operation of electrical. Download industrial power systems handbook donald beeman. Shields is a comprehensive study guide for the design of industrial and commercial electrical power systems as dictated by neutral grounding and groundfault protection practices. Abstract the main purpose of this paper is to acquaint the reader with various types of grounding systems prevalent in an electrical substation and their importance. Normally, generator and large deltay transformer secondaries are grounded.
Modern industrial plant electrical grounding system design. Fundamentals of power quality power quality through better wiring and gdiptigrounding practice david brender, p. He has worked as a consultant for design of grounding system for a number of power stations. However, the size of t,he power system back of the circuit breaker has a. Where an industrial power system includes powergenerating. Dunkijacobs, et al, industrial power systems grounding design handbook, publisher. It is most commonly a neutral conductor of a singlephase, 3wire system. It provides the theoretical background necessary for understanding problems related to grounding systems, such as safety and protection.
This course is intended to prepare the target persons with the ability to perform all electrical grounding system design for domestic, commercial and industrial facilities and ac substations. Industrial power system grounding design handbook j. Duncan glover, et al, power system analysis and design, 5th. This is a discussion of the basic principles behind grounding systems and how grounding is related to safety and the effective operation of circuit protection devices such as fuses and circuit breakers. One of the primary duties of electrical engineers in the petroleum industry is the design and construction of power distribution systems. Purchase industrial power engineering handbook 1st edition. About us we believe everything in the internet must be free. Industrial power system design in a utility environment.
Importance of grounding techniques 0 5 10 15 20 25 30 35 40 45. Design of grounding system for an electrical substation. Industrial power system grounding design handbook john. Fibrillation discharge limit of body current is used to determine the tolerable safety criteria for grounding system design 7. Grounding electrode system refers to grounding electrode conductors and all electrodes required or allowed by nec, as well as made, supplementary, and lightning protection system grounding electrodes. The second, and equally important, element of any ground system is the configuration of grounding conductors inside the building. Industrial power systems handbook beeman, donald on. Industrial power system grounding design handbook by j. Section 26 05 26, grounding and bonding for electrical systems. A design guide to neutral grounding of industrial power systems. Grounds for grounding provides a complete and thorough approach to the subject of designing electrical and electronic circuits and systems, blending theory and practice to demonstrate how a few basic rules can be applied across a broad range of applications. A grounding electrode system is a system where two or more grounding electrodes are connected together. Ieee std 142 2007 revision of ieee std 1421991 ieee recommended practice for grounding of industrial and commercial power systems sponsor power systems engineering committee of the ieee industry applications society approved 7 june 2007.
77 108 786 1439 1535 922 1034 1509 177 153 186 1357 450 1281 87 749 19 1177 134 707 649 717 621 1377 722 1149 954 497 412 407 763 1197 511 208 692 229 404 110 496 529 495 272 398